ABB
1SFA898217R7000PSTX570-690-70
PSTX570-690-70
Softstarter - ABB (PSTX) - PSTX570-690-70 - Rated voltage 400-690Vac - Supply voltage (50/60Hz) 100-250V - Rated current 570A - Rated power (380-400Vac) 315kW / (440-480Vac) 500HP - IP00 - RS485
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
1SFA898217R7000
Online Price
RM59,378.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
ABB - PSTX1SFA898217R7000
Description
Softstarter - ABB (PSTX) - PSTX570-690-70 - Rated voltage 400-690Vac - Supply voltage (50/60Hz) 100-250V - Rated current 570A - Rated power (380-400Vac) 315kW / (440-480Vac) 500HP - IP00 - RS485
Specifications
Primary brand
ABB
Main function
Softstarter
Product series / family name
PSTX
Network frequency
50/60 Hz
Functions
User defined
Bypass open
Auto restart
Auto phase sequence detection
Voltage sags detection
Switch for Inside Delta Connection
RUN Signal
By-pass Signal
FAULT Signal
Overload Signal
Stand-still brake
Keyhole mounting
Sequence start
Automatic restart
Kick start
HMI for settings
Real time clock
Event log
Emergency mode
Secure settings
Keypad password
Electronic overload Time-to-cool
Thyristor runtime measurement
Bypass open
Auto restart
Auto phase sequence detection
Voltage sags detection
Switch for Inside Delta Connection
RUN Signal
By-pass Signal
FAULT Signal
Overload Signal
Stand-still brake
Keyhole mounting
Sequence start
Automatic restart
Kick start
HMI for settings
Real time clock
Event log
Emergency mode
Secure settings
Keypad password
Electronic overload Time-to-cool
Thyristor runtime measurement
Rated impulse voltage (Uimp)
6 kV
Rated insulation voltage (Ui)
690 V
Communication protocol
RS485
Net Width (mm)
361 mm
Degree of protection
IP00
Technology used in component
Cooling system
Built-in bypass contactor
Bow thruster
Built-in bypass contactor
Bow thruster
Display type
LCD screen + LED indicators
Supply voltage
(50/60Hz) 100-250 V
Rated current
570 A
Rated active power (kW)
(380-400Vac) 315 kW
(500Vac) 400 kW
(690Vac) 560 kW
(500Vac) 400 kW
(690Vac) 560 kW
Rated power (HP)
(440-480Vac) 500 HP
(550-600Vac) 600 HP
(550-600Vac) 600 HP
Application type
Motor starting application
Centrifugal pump
Compressor
Conveyor belt (short)
Elevator
Centrifugal pump
Compressor
Conveyor belt (short)
Elevator
Contacts type
SPDT (Single Pole Double Throw) (K4; K5; K6)
Manufacturer product status
Commercialized
Rated Voltage (AC) - Phase-to-phase
400-690 V
Compliant with standard(s)
IEC60529
IEC60947-1
EN60947-4-2
IEC 60947-4-2 (EMC) Class A
CSA C22.2 No 14
UL508
CE
cULus
CCC
EAC
C-tick
IEC60947-1
EN60947-4-2
IEC 60947-4-2 (EMC) Class A
CSA C22.2 No 14
UL508
CE
cULus
CCC
EAC
C-tick
Mounting mode
Surface mounting
Analog inputs
PTC
Analog outputs
4-20mA; 0-20mA; 0-10V; 0-10mA
Digital inputs
Start
Stop
3 x programable inputs (In0; In1; In2)
Stop
3 x programable inputs (In0; In1; In2)
Digital outputs
K4 (programmable; RUN signal by default)
K5 (programmable; bypass signal by default)
K5 (programmable; FAULT signal by default)
K5 (programmable; bypass signal by default)
K5 (programmable; FAULT signal by default)
Degree of pollution
3
Protection functions
EOL protection
Locked rotor
Phase reversal
Current imbalance
Overvoltage
Undervoltage
Ground fault
Voltage imbalance
Voltage outputs
Overtemperature protection (external thermal sensor - PT100)
Overtemperature protection (external thermal sensor - PTC)
Power factor underload
Current underload
Current limit
Fieldbus failure
Extension IO failure
HMI failure
Max number of starts
Frequency range protection
Overtime starting protection
Locked rotor
Phase reversal
Current imbalance
Overvoltage
Undervoltage
Ground fault
Voltage imbalance
Voltage outputs
Overtemperature protection (external thermal sensor - PT100)
Overtemperature protection (external thermal sensor - PTC)
Power factor underload
Current underload
Current limit
Fieldbus failure
Extension IO failure
HMI failure
Max number of starts
Frequency range protection
Overtime starting protection
Type of terminals
Cable clamp
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - PSTX - Catalog | 15 Mar 2017 | English (US) |
ABB - PSR, PSE & PSTX - Catalog (rev G, 2020.01) | 06 Jan 2021 | English (US) |