ABB
ACS580-01-430A-4+B056ABB VSD/VFD - ACS580 - 3P - 380-480Vac - 430A / 250kW / 350HP
ABB VSD/VFD - ACS580 - 3P - 380-480Vac - 430A / 250kW / 350HP
Variable Speed/Frequency Drive (VSD/VFD) / Inverter - ABB (ACS580 series) - Rated input voltage 380Vac-480Vac (400Vac / 415Vac / 440Vac) (3-phase / 3P) - Rated current 430A (Nominal) - Rated power 250kW (Nominal) / 350HP (Light Overload; 440-480Vac) - IP55 / UL type 12 - Frame size R9 - with Modbus RTU / Modbus communication capability - Surface / wall mounting - with built-in EMC filter + Choke + STO Safe Torque OFF (SIL3 as per IEC 61511 / SILCL3 as per IEC62061 / PLe ISO13849-1) - with Assistant control panel - item code #3AUA0000083585
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
ACS580-01-430A-4+B056
Online Price
RM97,243.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Click on the colored tile to view a product selector for this product series:
ABB - ACS580ACS580-01-430A-4+B056
Description
Variable Speed/Frequency Drive (VSD/VFD) / Inverter - ABB (ACS580 series) - Rated input voltage 380Vac-480Vac (400Vac / 415Vac / 440Vac) (3-phase / 3P) - Rated current 430A (Nominal) - Rated power 250kW (Nominal) / 350HP (Light Overload; 440-480Vac) - IP55 / UL type 12 - Frame size R9 - with Modbus RTU / Modbus communication capability - Surface / wall mounting - with built-in EMC filter + Choke + STO Safe Torque OFF (SIL3 as per IEC 61511 / SILCL3 as per IEC62061 / PLe ISO13849-1) - with Assistant control panel - item code #3AUA0000083585
Specifications
Primary brand
ABB
Main function
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family name
ACS580 series
Network frequency
48-63 Hz
Functions
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
STO Safe Torque OFF (SIL3 as per IEC 61511 / SILCL3 as per IEC62061 / PLe ISO13849-1)
PID control
Energy optimizer
Limit view enable
Diagnostics
Pump and fan control parameter (PFC)
Assistant control panel
STO Safe Torque OFF (SIL3 as per IEC 61511 / SILCL3 as per IEC62061 / PLe ISO13849-1)
PID control
Energy optimizer
Limit view enable
Diagnostics
Pump and fan control parameter (PFC)
Assistant control panel
Design
EMC filter
Choke
Choke
Supply voltage (AC)
380Vac-480Vac (400Vac / 415Vac / 440Vac)
Type of network
3-phase / 3P
Rated current
430A (Nominal)
400A (Light Overload; 380-415Vac)
363A (Heavy Duty; 380-415Vac)
414A (Light Overload; 440-480Vac)
361A (Heavy Duty; 440-480Vac)
617A (380-415Vac) maximum
542A (440-480Vac)
400A (Light Overload; 380-415Vac)
363A (Heavy Duty; 380-415Vac)
414A (Light Overload; 440-480Vac)
361A (Heavy Duty; 440-480Vac)
617A (380-415Vac) maximum
542A (440-480Vac)
Rated active power (kW)
250kW (Nominal)
250kW (Light Overload; 380-415Vac)
200kW (Heavy Duty; 380-415Vac)
250kW (Light Overload; 380-415Vac)
200kW (Heavy Duty; 380-415Vac)
Rated power (HP)
350HP (Light Overload; 440-480Vac)
300HP (Heavy Duty; 440-480Vac)
300HP (Heavy Duty; 440-480Vac)
Communication protocol
Modbus RTU
Modbus
Modbus
Net Width (mm)
380 mm
Mounting mode
Surface / wall
Digital inputs
1 x digital input (24Vdc) (DI1 START/STOP)
1 x digital input (24Vdc) (DI2 FWD/REV)
2 x digital inputs (24vdc) (DI3 / DI4 constant speed selection)
1 x digital input (24Vdc) (DI5 ramp pair selection)
1 x digital input (24Vdc) (DI6)
1 x digital input (24Vdc) (DI2 FWD/REV)
2 x digital inputs (24vdc) (DI3 / DI4 constant speed selection)
1 x digital input (24Vdc) (DI5 ramp pair selection)
1 x digital input (24Vdc) (DI6)
Digital outputs
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO1 READY)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO2 RUNNING)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO3 FAULT)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO2 RUNNING)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO3 FAULT)
Analog inputs
1 x analog input (0-10Vdc) (AI1 External frequency reference)
1 x analog input (0-10Vdc) (AI2)
1 x analog input (0-10Vdc) (AI2)
Analog outputs
1 x analog output (0-20mA) (AO1 inverter output frequency)
1 x analog output (0-20mA) (AO2 inverter output current)
1 x analog output (0-20mA) (AO2 inverter output current)
Degree of protection
IP55
UL type 12
UL type 12
Dimensions
Frame size R9
Ambient air temperature for operation
-40...+70 °C
Power dissipation/losses
6036 W
Application type
General purpose drives
blowers
centrifuges
compressors
conveyors
fans
mills
pumps
separators
mixers
dryers
pelletizers
presses
winders
extruders
injection
molding machines
bleaching machines
drum
washers
jet dyeing
machines
stenter machines
stretchers
chippers
feeders
pickers
drying kilns
compressors
pump stations
fans
irrigators
sorters
conveyors
blowers
centrifuges
compressors
conveyors
fans
mills
pumps
separators
mixers
dryers
pelletizers
presses
winders
extruders
injection
molding machines
bleaching machines
drum
washers
jet dyeing
machines
stenter machines
stretchers
chippers
feeders
pickers
drying kilns
compressors
pump stations
fans
irrigators
sorters
conveyors
Order code / Manufacturer SKU
3AUA0000083585
Manufacturer product status
Commercialized
Compliant with standard(s)
CE
IEC60721-3-1 Class 1C2; 1S2
IEC60721-3-2 Class 2C2; 2S2
IEC60721-3-3 Class 3C2; 3S2
IEC61508 ed2 SIL 3
IEC61511 SIL 3
IEC62061 SIL CL 3
EN ISO13849-1 PL e
EN61800-3
EN61800-5-1
EN61800-5-2
EN50598-2
cUL
UL
EAC
RoHS
TUV Nord
IEC60721-3-1 Class 1C2; 1S2
IEC60721-3-2 Class 2C2; 2S2
IEC60721-3-3 Class 3C2; 3S2
IEC61508 ed2 SIL 3
IEC61511 SIL 3
IEC62061 SIL CL 3
EN ISO13849-1 PL e
EN61800-3
EN61800-5-1
EN61800-5-2
EN50598-2
cUL
UL
EAC
RoHS
TUV Nord
Net width (in)
15 in
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - ACS580 - Catalog (2017).pdf | 01 Jun 2020 | English (US) |
ABB - AC drives and softstarters - Catalog.pdf | 30 Sep 2018 | English (US) |
ABB - ACS580 - Catalog (2018).pdf | 01 Jun 2020 | English (US) |
ABB - ACS580 - US - Catalog.pdf | 01 Jun 2020 | English (US) |