ABB
ACS880-01-017A-3ABB VSD/VFD - ACS880 - 3P - 380-415Vac - 17A / 7.5kW
ABB VSD/VFD - ACS880 - 3P - 380-415Vac - 17A / 7.5kW
Variable Speed/Frequency Drive (VSD/VFD) / Inverter - ABB (ACS880 series) - Rated input voltage 380Vac-415Vac (400Vac) (3-phase / 3P) - Rated current 17A (Nominal; 400Vac) - Rated power 7.5kW (Nominal; 400Vac) - IP21 - Frame size R2 - with Modbus RTU / Modbus communication capability - Surface / wall mounting - with built-in Brake chopper + Safe Torque OFF (STO) + Direct Torque Control (DTC)
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
ACS880-01-017A-3
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
ABB - ACS880ACS880-01-017A-3
Description
Variable Speed/Frequency Drive (VSD/VFD) / Inverter - ABB (ACS880 series) - Rated input voltage 380Vac-415Vac (400Vac) (3-phase / 3P) - Rated current 17A (Nominal; 400Vac) - Rated power 7.5kW (Nominal; 400Vac) - IP21 - Frame size R2 - with Modbus RTU / Modbus communication capability - Surface / wall mounting - with built-in Brake chopper + Safe Torque OFF (STO) + Direct Torque Control (DTC)
Specifications
Primary brand
ABB
Main function
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family name
ACS880 series
Network frequency
50-60 Hz
Functions
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Safe Torque OFF (STO)
Direct Torque Control (DTC)
PID control
Energy optimizer
Diagnostics
Safe Torque OFF (STO)
Direct Torque Control (DTC)
PID control
Energy optimizer
Diagnostics
Design
Brake chopper
Supply voltage (AC)
380Vac-415Vac (400Vac)
Type of network
3-phase / 3P
Rated current
17A (Nominal; 400Vac)
16A (Light Overload; 400Vac)
12.6A (Heavy Duty; 400Vac)
21A maximum
16A (Light Overload; 400Vac)
12.6A (Heavy Duty; 400Vac)
21A maximum
Rated active power (kW)
7.5kW (Nominal; 400Vac)
7.5kW (Light Overload; 400Vac)
5.5kW (Heavy Duty; 400Vac)
7.5kW (Light Overload; 400Vac)
5.5kW (Heavy Duty; 400Vac)
Protection functions
Safe Torque OFF (STO)
Stop emergency
Brake control
Limited/ Maximum speed of the motor
Prevention of unexpected startup
Stop emergency
Brake control
Limited/ Maximum speed of the motor
Prevention of unexpected startup
Communication protocol
Modbus RTU
Modbus
Modbus
Net Width (mm)
155 mm
Mounting mode
Surface / wall
Digital inputs
1 x digital input (24Vdc) (XDI-DI1 START/STOP)
1 x digital input (24Vdc) (XDI-DI2 FWD/REV)
1 x digital input (24Vdc) (XDI-DI3 RESET)
1 x digital input (24Vdc) (XDI-DI4 Acceleration and deceleration select)
1 x digital input (24Vdc) (XDI-DI5 constant speed selection)
1 x digital input (24Vdc) (XDI-DI6)
1 x digital input (24Vdc) (XD24-DIIL Digital interlock)
1 x digital input (24Vdc; can be used as input or output) (DIO1 READY)
1 x digital input (24Vdc; can be used as input or output) (DIO2 RUNNING)
1 x digital input (must be closed for drive to start) (XSTO-IN1)
1 x digital input (must be closed for drive to start) (XSTO-IN2)
1 x digital input (24Vdc) (XDI-DI2 FWD/REV)
1 x digital input (24Vdc) (XDI-DI3 RESET)
1 x digital input (24Vdc) (XDI-DI4 Acceleration and deceleration select)
1 x digital input (24Vdc) (XDI-DI5 constant speed selection)
1 x digital input (24Vdc) (XDI-DI6)
1 x digital input (24Vdc) (XD24-DIIL Digital interlock)
1 x digital input (24Vdc; can be used as input or output) (DIO1 READY)
1 x digital input (24Vdc; can be used as input or output) (DIO2 RUNNING)
1 x digital input (must be closed for drive to start) (XSTO-IN1)
1 x digital input (must be closed for drive to start) (XSTO-IN2)
Digital outputs
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO1 READY)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO2 RUNNING)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO3 FAULT)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO2 RUNNING)
1 x digital output (SPDT rly. contact; 2A 250Vac/30Vdc) (RO3 FAULT)
Analog inputs
1 x analog input (0-10Vdc / 2-10Vdc) (XAI-AI1 Speed reference)
1 x analog input (0-20mA / 4-20mA) (XAI-AI2)
1 x analog input (0-20mA / 4-20mA) (XAI-AI2)
Analog outputs
1 x analog output (0-20mA) (XAO-AO1 motor speed rpm)
1 x analog output (0-20mA) (XAO-AO2 motor current)
1 x analog output (0-20mA) (XAO-AO2 motor current)
Degree of protection
IP21
Dimensions
Frame size R2
Ambient air temperature for operation
-40...+70 °C
Power dissipation/losses
232 W
Application type
Machinery drives
mixers
centrifuges
conveyors
cranes
requiring accurate speed and torque control
mixers
centrifuges
conveyors
cranes
requiring accurate speed and torque control
Manufacturer product status
Commercialized
Compliant with standard(s)
CE
IEC60721-3-1 Class 1C2; 1S2
IEC60721-3-2 Class 2C2; 2S2
IEC60721-3-3 Class 3C2; 3S2
EN61800-3
EN61800-5-1
EN61800-5-2
cUL
UL
CSA
GOST R
EAC
RoHS
ABS
Bureau Veritas
CCS
DNV GL
Lloyd's
NK
RINA
TUV Nord
IEC60721-3-1 Class 1C2; 1S2
IEC60721-3-2 Class 2C2; 2S2
IEC60721-3-3 Class 3C2; 3S2
EN61800-3
EN61800-5-1
EN61800-5-2
cUL
UL
CSA
GOST R
EAC
RoHS
ABS
Bureau Veritas
CCS
DNV GL
Lloyd's
NK
RINA
TUV Nord
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - ACS380_ACS880 - Catalog.pdf | 01 Jun 2020 | English (US) |
ABB - ACS880 - Catalog.pdf | 01 Jun 2020 | English (US) |