Schneider Electric
ATS01N232QNAltistart 01 series - 15kW / 32A - 342-457Vac (3-phase)
Altistart 01 series - 15kW / 32A - 342-457Vac (3-phase)
Soft-starter with 2-controlled phases + built-in bypass contact. + built-in control pwr. supp. - for asynchronous mtr. - Schneider Electric (Altistart 01 series) - Rated output 15kW / 32A - Supply voltage 342-457Vac (380Vac / 400Vac / 415Vac / 440Vac nom.; 50/60Hz) (3-phase (3P)) - Control voltage 24Vac / 24Vdc - Class 10 - screw connections - IP20 - DIN rail
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
ATS01N232QN
Online Price
RM 4,294.50
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Click on the colored tile to view a product selector for this product series:
Schneider Electric - Altistart 01ATS01N232QN
Description
Soft-starter with 2-controlled phases + built-in bypass contact. + built-in control pwr. supp. - for asynchronous mtr. - Schneider Electric (Altistart 01 series) - Rated output 15kW / 32A - Supply voltage 342-457Vac (380Vac / 400Vac / 415Vac / 440Vac nom.; 50/60Hz) (3-phase (3P)) - Control voltage 24Vac / 24Vdc - Class 10 - screw connections - IP20 - DIN rail
Specifications
Primary brand
Schneider Electric
Secondary brand
Telemecanique
Main function
Soft starter
Product series / family name
Altistart series
Sub-range name
Altistart 01 series
Functions
Soft-starter
Design
2-controlled phases
built-in bypass contact.
built-in control pwr. supp.
for asynchronous mtr.
built-in bypass contact.
built-in control pwr. supp.
for asynchronous mtr.
Supply voltage (AC)
342-457Vac (380Vac / 400Vac / 415Vac / 440Vac nom.; 50/60Hz)
Type of network
3-phase (3P)
Rated current
32A nom.
Rated active power (kW)
15kW (3-phase)
Connection type
screw connections
Control Voltage (AC)
24Vac
Control Voltage (DC)
24Vdc
Mounting mode
DIN rail
Degree of protection
IP20
Dimensions
H154mm x W45mm x D130.7mm
Ambient air temperature for operation
(without derating) +14...+104°F / -10...+40 °C
(with current derating of 2% per °C) +104...+122°F / +40...+50 °C
(with current derating of 2% per °C) +104...+122°F / +40...+50 °C
Ambient air temperature for storage
-13...158°F / -25...70 °C
Power dissipation/losses
(at full load and at end of starting) 4.5 W
(in transient state) 324.5 W
(in transient state) 324.5 W
Application type
Control of asynchronous motors
Conveyors
Conveyor belts
Compressors
Automatic doors and gates
Pumps
Fans
Overhead traveling Cranes (Horizontal Loads)
Belt-driven machinery
Conveyors
Conveyor belts
Compressors
Automatic doors and gates
Pumps
Fans
Overhead traveling Cranes (Horizontal Loads)
Belt-driven machinery
Manufacturer product status
Commercialized
Compliant with standard(s)
CSA
CE
C-Tick
GOST
UL
CCC
IEC/EN 60947-4-2
B44.1-96/ASME A17.5 for starter wired to the motor delta terminal
CE
C-Tick
GOST
UL
CCC
IEC/EN 60947-4-2
B44.1-96/ASME A17.5 for starter wired to the motor delta terminal
Class
Class 10
Benefits
The Altistart 01 soft starter operates either as a torque limiter on starting or as a soft start/soft stop unit for asynchronous motors.
Using the Altistart 01 starter enhances the starting performance of asynchronous motors by allowing them to start gradually and in a controlled manner.
It helps to prevent mechanical shocks (which cause wear and tear) and subsequent maintenance work and production downtime.
The Altistart U01 limits the starting torque and current peaks on starting on machines that do not require a high starting torque.
It is designed for simple applications e.g. conveyors / conveyor belts / pumps / fans / compressors / automatic doors and gates / small cranes / belt-driven machinery etc.
The Altistart 01 is compact and easy to install. It also can be mounted side-by-side.
It complies with standards IEC/EN 60947-4-2 / carries UL / CSA / C-Tick / CCC certifications and CE marking.
Using the Altistart 01 starter enhances the starting performance of asynchronous motors by allowing them to start gradually and in a controlled manner.
It helps to prevent mechanical shocks (which cause wear and tear) and subsequent maintenance work and production downtime.
The Altistart U01 limits the starting torque and current peaks on starting on machines that do not require a high starting torque.
It is designed for simple applications e.g. conveyors / conveyor belts / pumps / fans / compressors / automatic doors and gates / small cranes / belt-driven machinery etc.
The Altistart 01 is compact and easy to install. It also can be mounted side-by-side.
It complies with standards IEC/EN 60947-4-2 / carries UL / CSA / C-Tick / CCC certifications and CE marking.
Degree of pollution
2
Related Documents
Name | Last Update | Language |
---|---|---|
Download official PDF datasheet for ATS01N232QN from Schneider Electric | 18 Jun 2021 | English (US) |
Schneider Electric - Altistart 01 - Catalogue - Edition 2014.pdf | 08 Aug 2022 | English (US) |
Schneider Electric - Altistart 01 - Catalogue - Edition 2020.pdf | 08 Aug 2022 | English (US) |