ATS22C25QAltistart 22 series - 132kW / 250A - 230Vac-440Vac (3-phase)
Altistart 22 series - 132kW / 250A - 230Vac-440Vac (3-phase)
Soft-starter with 3-controlled phases (configurable voltage ramp) + built-in bypass contact. - Schneider Electric (Altistart 22 series) - Rated output 132kW / 250A - Supply voltage 196-484Vac (230Vac / 240Vac / 400Vac / 480Vac nom.; 50/60Hz) (3-phase (3P)) - Control voltage 220Vac - Class 10 - screw connections - IP00 - with Modbus communication capability - Wall mounting
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
ATS22C25Q
Online Price
RM 28,395.00
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Click on the colored tile to view a product selector for this product series:
Schneider Electric - Altistart 22ATS22C25Q
Description
Soft-starter with 3-controlled phases (configurable voltage ramp) + built-in bypass contact. - Schneider Electric (Altistart 22 series) - Rated output 132kW / 250A - Supply voltage 196-484Vac (230Vac / 240Vac / 400Vac / 480Vac nom.; 50/60Hz) (3-phase (3P)) - Control voltage 220Vac - Class 10 - screw connections - IP00 - with Modbus communication capability - Wall mounting
Specifications
Primary brand
Schneider Electric
Secondary brand
Telemecanique
Main function
Soft starter
Product series / family name
Altistart series
Sub-range name
Altistart 22 series
Functions
Soft-starter
Design
3-controlled phases (configurable voltage ramp)
built-in bypass contact.
built-in bypass contact.
Supply voltage (AC)
196-484Vac (230Vac / 240Vac / 400Vac / 480Vac nom.; 50/60Hz)
Type of network
3-phase (3P)
Rated current
250A nom.
Rated active power (kW)
75kW (230Vac)
132kW (400Vac)
132kW (440Vac)
110kW (230Vac; mtr. delta connection)
220kW (400Vac; mtr. delta connection)
220kW (440Vac; mtr. delta connection)
132kW (400Vac)
132kW (440Vac)
110kW (230Vac; mtr. delta connection)
220kW (400Vac; mtr. delta connection)
220kW (440Vac; mtr. delta connection)
Connection type
screw connections
Control Voltage (AC)
220Vac
Communication protocol
Modbus
Mounting mode
Wall mounting
Digital inputs
3 x digital inputs (24Vdc; source) (LI1-LI3)
Digital outputs
1 x digital output (C/O SPDT rly. contact) (R1)
1 x digital output (C/O SPDT rly. contact) (R2)
1 x digital output (C/O SPDT rly. contact) (R2)
Analog inputs
1 x analog input (PTC)
Degree of protection
IP00
Dimensions
H425mm x W206mm x D229mm
Ambient air temperature for operation
(without derating) +14...+104°F / -10...+40 °C
(with current derating 2.2% per °C) +104...+140°F / +40...+60 °C
(with current derating 2.2% per °C) +104...+140°F / +40...+60 °C
Ambient air temperature for storage
-13...158°F / -25...70 °C
Power dissipation/losses
129 W
Application type
Control of asynchronous motors
Conveyors
Conveyor belts
Compressors
Turbines
Lifting screw
Agitator
Pumps
Fans
Refiner
Mixer
Conveyors
Conveyor belts
Compressors
Turbines
Lifting screw
Agitator
Pumps
Fans
Refiner
Mixer
Manufacturer product status
Commercialized
Compliant with standard(s)
CSA
CE
C-Tick
GOST
UL
CCC
IEC/EN 60947-4-2
EMC Class A
CE
C-Tick
GOST
UL
CCC
IEC/EN 60947-4-2
EMC Class A
Class
Class 10
Benefits
Altistart 22 soft start/soft stop units support the controlled starting and stopping (via voltage and torque) of three-phase squirrel cage asynchronous motors for power ratings ranging from 4kW to 400kW.
They are supplied ready for use in standard applications with class 10 motor protection.
Altistart 22 soft start/soft stop units have been designed to meet the performance requirements of applications where ruggedness security of personnel and equipment and ease of setup are a priority.
The bypass function (based on a bypass contactor) has been made easier to use by integrating it into the starter.
This approach suits applications where it may be necessary to bypass the starter at the end of starting in order e.g. to limit the starter's heat dissipation.
Altistart 22 soft start/soft stop units have an integrated display terminal that allows the user to change both the programming and the adjustment or monitoring parameters in order to adapt and customize the application in line with customer needs.
They also feature an integrated thermal motor protection function as well as machine monitoring functionality and offer immediate installation setup capability using SoMove setup software.
They are supplied ready for use in standard applications with class 10 motor protection.
Altistart 22 soft start/soft stop units have been designed to meet the performance requirements of applications where ruggedness security of personnel and equipment and ease of setup are a priority.
The bypass function (based on a bypass contactor) has been made easier to use by integrating it into the starter.
This approach suits applications where it may be necessary to bypass the starter at the end of starting in order e.g. to limit the starter's heat dissipation.
Altistart 22 soft start/soft stop units have an integrated display terminal that allows the user to change both the programming and the adjustment or monitoring parameters in order to adapt and customize the application in line with customer needs.
They also feature an integrated thermal motor protection function as well as machine monitoring functionality and offer immediate installation setup capability using SoMove setup software.
Degree of pollution
2
Related Documents
Name | Last Update | Language |
---|---|---|
Download official PDF datasheet for ATS22C25Q from Schneider Electric | 18 Jun 2021 | English (US) |
Schneider Electric - Altistart 22 - Catalogue - Edition 2014.pdf | 08 Aug 2022 | English (US) |
Schneider Electric - Altistart 22 - Catalogue - Edition 2017.pdf | 08 Aug 2022 | English (US) |