Schneider Electric
ATS48D22QAltistart 48 series - 11kW / 21A - 230Vac-415Vac (3-phase)
Altistart 48 series - 11kW / 21A - 230Vac-415Vac (3-phase)
Soft-starter with 3-controlled phases (Torque Control System; TCS) + FIPIO protocol - for asynchronous mtr. - Schneider Electric (Altistart 48 series) - Rated output 11kW / 22A - Supply voltage 198-457Vac (230Vac / 380Vac / 400Vac / 415Vac nom.; 50/60Hz) (3-phase (3P)) - Class 10 / Class 20 - screw connections - IP20 - with Modbus / Modbus TCP / DeviceNet / PROFIBUS DP communication capability - Wall mounting
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
ATS48D22Q
Online Price
RM11,460.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Schneider Electric - Altistart 48ATS48D22Q
Description
Soft-starter with 3-controlled phases (Torque Control System; TCS) + FIPIO protocol - for asynchronous mtr. - Schneider Electric (Altistart 48 series) - Rated output 11kW / 22A - Supply voltage 198-457Vac (230Vac / 380Vac / 400Vac / 415Vac nom.; 50/60Hz) (3-phase (3P)) - Class 10 / Class 20 - screw connections - IP20 - with Modbus / Modbus TCP / DeviceNet / PROFIBUS DP communication capability - Wall mounting
Specifications
Primary brand
Schneider Electric
Secondary brand
Telemecanique
Main function
Soft starter
Product series / family name
Altistart series
Sub-range name
Altistart 48 series
Functions
Soft-starter
TCS (Torque Control System)
TCS (Torque Control System)
Design
3-controlled phases (Torque Control System; TCS)
FIPIO protocol
for asynchronous mtr.
bypass available for as an option
FIPIO protocol
for asynchronous mtr.
bypass available for as an option
Supply voltage (AC)
198-457Vac (230Vac / 380Vac / 400Vac / 415Vac nom.; 50/60Hz)
Type of network
3-phase (3P)
Rated current
22A (standard applications)
17A (severe applications)
38A (standard application; mtr. delta connection)
29A (severe applications; mtr. delta connection)
21A factory setting current
17A (severe applications)
38A (standard application; mtr. delta connection)
29A (severe applications; mtr. delta connection)
21A factory setting current
Rated active power (kW)
5.5kW (230Vac; standard applications; supply line connection)
11kW (400Vac; standard applications; supply line connection)
4kW (230Vac; severe applications; supply line connection)
7.5kW (400Vac; severe applications; supply line connection)
9kW (230Vac; standard applications; delta connection)
18.5kW (400Vac; standard applications; delta connection)
7.5kW (230Vac; severe applications; delta connection)
15kW (400Vac; severe applications; delta connection)
11kW (400Vac; standard applications; supply line connection)
4kW (230Vac; severe applications; supply line connection)
7.5kW (400Vac; severe applications; supply line connection)
9kW (230Vac; standard applications; delta connection)
18.5kW (400Vac; standard applications; delta connection)
7.5kW (230Vac; severe applications; delta connection)
15kW (400Vac; severe applications; delta connection)
Connection type
screw connections
Communication protocol
Modbus
Modbus TCP
DeviceNet
PROFIBUS DP
Modbus TCP
DeviceNet
PROFIBUS DP
Mounting mode
Wall mounting
Digital inputs
1 x digital input (24Vdc; source) (STOP)
1 x digital input (24Vdc; source) (RUN)
2 x digital inputs (24Vdc; source) (LI3-LI4)
1 x digital input (24Vdc; source) (RUN)
2 x digital inputs (24Vdc; source) (LI3-LI4)
Digital outputs
1 x digital output (24Vdc) (LO1; programmable)
1 x digital output (24Vdc) (LO2; programmable)
1 x digital output (NO rly. contact) (FAULT)
1 x digital output (NO rly. contact) (end of starting)
1 x digital output (NO rly. contact) (motor powered)
1 x digital output (24Vdc) (LO2; programmable)
1 x digital output (NO rly. contact) (FAULT)
1 x digital output (NO rly. contact) (end of starting)
1 x digital output (NO rly. contact) (motor powered)
Analog outputs
1 x analog output (0-20mA / 4-20mA)
Degree of protection
IP20
Dimensions
H275mm x W160mm x D190mm
Ambient air temperature for operation
(without derating) -10...+40 °C
(with current derating of 2% per °C) +40...+60 °C
(with current derating of 2% per °C) +40...+60 °C
Ambient air temperature for storage
-25...+70 °C
Power dissipation/losses
(standard applications) 695 W
(severe applications) 580 W
(severe applications) 580 W
Application type
Control of asynchronous motors
Heavy-duty industry
Conveyors
Compressors
Elevator
Lifting screw
Agitator
Pumps
Fans
Refiner
Mixer
Grinder
Heavy-duty industry
Conveyors
Compressors
Elevator
Lifting screw
Agitator
Pumps
Fans
Refiner
Mixer
Grinder
Manufacturer product status
Phasing out
Product replaced by
ATS480D22Y
Compliant with standard(s)
CSA
CE
C-Tick
DNV
GOST
NOM 117
UL
CCC
SEPRO
TCF
IEC/EN 60947-4-2
EMC Class A and B
CE
C-Tick
DNV
GOST
NOM 117
UL
CCC
SEPRO
TCF
IEC/EN 60947-4-2
EMC Class A and B
Class
Class 10
Class 20
Class 20
Benefits
The Altistart 48 soft start/soft stop unit is a controller with 6 thyristors used for torque-controlled soft starting and stopping of three-phase squirrel cage asynchronous motors for power ratings between 4kW and 900kW.
It offers soft starting and deceleration functions along with machine and motor protection functions as well as functions for communicating with control systems.
These functions are designed for use in the most common applications for centrifugal machines / pumps / fans / compressors and conveyors -- which are primarily to be found in the construction food and beverage and chemical industries.
The high-performance algorithms of the Altistart 48 contribute significantly to its ruggedness safety and ease of setup.
The Altistart 48 soft start/soft stop unit is a cost-effective solution which can
- reduce machine operating costs by reducing mechanical stress and improving machine availability
- reduce the stress on the electrical distribution system by reducing line current peaks and voltage drops during motor starts
The Altistart 48 soft start/soft stop unit offer comprises 2 ranges
- three-phase voltages 230Vac to 415Vac 50/60Hz
- three-phase voltages 208Vac to 690Vac 50/60Hz
In each voltage range the Altistart 48 soft start/soft stop units are sized for standard and severe applications.
The Altistart 48 soft start/soft stop unit 1 is supplied ready for use in a standard application with class 10 motor protection.
It comprises an integrated display terminal which can be used to modify the programming -- adjustment or monitoring functions in order to adapt and customize the application to meet individual customer requirements.
Drive performance functions
- exclusive Altistart torque control (patented by Schneider Electric)
- constant control of the torque supplied to the motor during acceleration and deceleration periods (significantly reducing pressure surges)
- ease of adjusting the ramp and the starting torque
- option of bypassing the starter using a contactor 3 at the end of the starting period whilst maintaining electronic protection (bypass function)
- wide frequency tolerance for generator set power supplies
- option of connecting the starter to the motor delta terminals in series with each winding
Machine and motor protection functions
- built-in motor thermal protection
- processing of information from PTC thermal probes
- monitoring of the starting time
- motor preheating function
- protection against underloads and overcurrents in steady state
Functions to ease integration into control systems
- 4 logic inputs + 2 logic outputs + 3 relay outputs and 1 analog output
- plug-in I/O connectors
- function for configuring a second motor and easy-to-adapt settings
- display of electrical values -- the state of the load and the operating time
- RS485 serial link for connection to Modbus serial link
It offers soft starting and deceleration functions along with machine and motor protection functions as well as functions for communicating with control systems.
These functions are designed for use in the most common applications for centrifugal machines / pumps / fans / compressors and conveyors -- which are primarily to be found in the construction food and beverage and chemical industries.
The high-performance algorithms of the Altistart 48 contribute significantly to its ruggedness safety and ease of setup.
The Altistart 48 soft start/soft stop unit is a cost-effective solution which can
- reduce machine operating costs by reducing mechanical stress and improving machine availability
- reduce the stress on the electrical distribution system by reducing line current peaks and voltage drops during motor starts
The Altistart 48 soft start/soft stop unit offer comprises 2 ranges
- three-phase voltages 230Vac to 415Vac 50/60Hz
- three-phase voltages 208Vac to 690Vac 50/60Hz
In each voltage range the Altistart 48 soft start/soft stop units are sized for standard and severe applications.
The Altistart 48 soft start/soft stop unit 1 is supplied ready for use in a standard application with class 10 motor protection.
It comprises an integrated display terminal which can be used to modify the programming -- adjustment or monitoring functions in order to adapt and customize the application to meet individual customer requirements.
Drive performance functions
- exclusive Altistart torque control (patented by Schneider Electric)
- constant control of the torque supplied to the motor during acceleration and deceleration periods (significantly reducing pressure surges)
- ease of adjusting the ramp and the starting torque
- option of bypassing the starter using a contactor 3 at the end of the starting period whilst maintaining electronic protection (bypass function)
- wide frequency tolerance for generator set power supplies
- option of connecting the starter to the motor delta terminals in series with each winding
Machine and motor protection functions
- built-in motor thermal protection
- processing of information from PTC thermal probes
- monitoring of the starting time
- motor preheating function
- protection against underloads and overcurrents in steady state
Functions to ease integration into control systems
- 4 logic inputs + 2 logic outputs + 3 relay outputs and 1 analog output
- plug-in I/O connectors
- function for configuring a second motor and easy-to-adapt settings
- display of electrical values -- the state of the load and the operating time
- RS485 serial link for connection to Modbus serial link
Degree of pollution
3
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - Altistart 48 - Catalogue.pdf | 08 Aug 2022 | English (US) |