Schneider Electric
ATV61HC16YAltivar 61 series - 160kW / 200A - 425-759Vac (3-phase)
Altivar 61 series - 160kW / 200A - 425-759Vac (3-phase)
Variable Speed / Frequency Drive (VSD/VFD) / Inverter with built-in EMC filter (class C3) + built-in heatsnk. - coated version - IP20 / UL type 1 version - Schneider Electric (Altivar 61 series) - Rated output 160kW / 200A - Supply voltage 425-759Vac (480Vac / 500Vac / 600Vac / 690Vac nom.) (3-phase (3P)) - with Modbus / CANopen communication capability - Wall mounting - conformal coating (reinforced version) - with detachable graphical display + keypad
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
ATV61HC16Y
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Schneider Electric - Altivar 61-61PlusATV61HC16Y
Description
Variable Speed / Frequency Drive (VSD/VFD) / Inverter with built-in EMC filter (class C3) + built-in heatsnk. - coated version - IP20 / UL type 1 version - Schneider Electric (Altivar 61 series) - Rated output 160kW / 200A - Supply voltage 425-759Vac (480Vac / 500Vac / 600Vac / 690Vac nom.) (3-phase (3P)) - with Modbus / CANopen communication capability - Wall mounting - conformal coating (reinforced version) - with detachable graphical display + keypad
Additional Information
-- ATV61HC16Y item has been OBSOLETE. Kindly contact us for further details. --
Specifications
Primary brand
Schneider Electric
Secondary brand
Telemecanique
Main function
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family name
Altivar series
Sub-range name
Altivar 61 series
Network frequency
(output) 0.1-500 Hz
Functions
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
U/F ratio (2 points / 5 points / energy saving)
Sensorless flux vector control (standard / energy saving)
Vector control without speed feedback
120% of the nominal motor torque
U/F ratio (2 points / 5 points / energy saving)
Sensorless flux vector control (standard / energy saving)
Vector control without speed feedback
120% of the nominal motor torque
Design
built-in EMC filter (class C3)
built-in heatsnk.
coated version
built-in heatsnk.
coated version
Supply voltage (AC)
425-759Vac (480Vac / 500Vac / 600Vac / 690Vac nom.)
Display
detachable graphical display + keypad
Type of network
3-phase (3P)
Rated current
200A (500Vac; 2.5kHz)
180A (690Vac; 2.5kHz)
240A max. current (for 60s)
180A (690Vac; 2.5kHz)
240A max. current (for 60s)
Rated active power (kW)
160kW (690Vac)
132kW (500Vac)
132kW (500Vac)
Communication protocol
Modbus
CANopen
CANopen
Mounting mode
Wall mounting
Digital inputs
5 x digital inputs (24Vdc; sink/source) (LI1-LI5; programmable)
1 x digital input (24Vdc; sink/source) (LI6; programmable as discrete or PTC input)
1 x digital input (24Vdc) (PWR safety input)
1 x digital input (24Vdc; sink/source) (LI6; programmable as discrete or PTC input)
1 x digital input (24Vdc) (PWR safety input)
Digital outputs
1 x digital output (C/O SPDT rly. contact) (R1)
1 x digital output (NO rly. contact) (R2)
1 x digital output (NO rly. contact) (R2)
Analog inputs
1 x analog input (-10...+10Vdc)
1 x analog input (0-10Vdc / 0-20mA)
1 x analog input (0-10Vdc / 0-20mA)
Analog outputs
1 x analog output (0-10Vdc / 0-20mA)
Degree of protection
IP20
UL type 1
UL type 1
Dimensions
H1190mm x W340mm x D377mm
Chemical resistance
conformal coating (reinforced version)
Current consumption
182A (500Vac)
158.9A (600Vac)
163A (690Vac)
158.9A (600Vac)
163A (690Vac)
Application type
Control of asynchronous motors
Control of synchronous motors
Ventilation machine
Pumps
Fans
Control of synchronous motors
Ventilation machine
Pumps
Fans
Manufacturer product status
Phasing out
Compliant with standard(s)
CSA
CE
C-Tick
DNV
GOST
NOM 117
UL
EN/IEC 61800-3 (environment 1 and 2; category C3)
EN/IEC 61800-5-1
EN 55011 (class A; group 2)
IEC 60721-3-3 class 3C2
EN/IEC 60529
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-6
IEC 61000-4-11
CE
C-Tick
DNV
GOST
NOM 117
UL
EN/IEC 61800-3 (environment 1 and 2; category C3)
EN/IEC 61800-5-1
EN 55011 (class A; group 2)
IEC 60721-3-3 class 3C2
EN/IEC 60529
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-6
IEC 61000-4-11
Benefits
The Altivar 61 drive is a frequency inverter for 0.75kW / 1HP to 2400kW 3-phase synchronous and asynchronous motors.
It has been designed for common fluid management applications in industrial and commercial buildings and infrastructures.
The Altivar 61 can increase the performance of equipment and reduce operating costs in buildings by optimizing energy consumption whilst improving user comfort.
The drive is designed to be environmentally-friendly
- Energy saving with a reduction in energy consumption of 70% for ventilation applications and 50% for pumping applications
- Reduction of fluid losses in distribution networks
- Use of 80% recyclable materials
- the Altivar 61 drive conforms to environmental standard ISO 14040 which defines a critical analysis of the product's impact on the environment
The Altivar 61 drive has been developed to meet the requirements of directives regarding the protection of the environment (RoHS / REACH / WEEE) as well as those of European Directives to obtain the CE mark.
The entire range is UL / CSA / DNV / C-Tick / NOM and GOST certified and conforms to international standards relating to electrical industrial control equipment IEC/EN 61800-2 and IEC/EN 61800-5-1.
The need for electromagnetic compatibility was taken into account at the outset when designing the drive. The entire range conforms to international standard IEC/EN 61800-3.
The Altivar 61 drive complies with the requirements of safety standards for applications in explosive atmospheres (ATEX). Please refer to the ATEX guide which is available on our website www.schneider-electric.com.
The Altivar 61 range offers numerous variants to meet the requirements of applications in a wide variety of fields and in very harsh environments.
With these variants -- the Altivar 61 range offers ready-to-use or modular solutions that can adapt to your needs.
Its numerous and comprehensive options enable it to be adapted and incorporated into electrical installations / sophisticated control systems / infrastructures and building management systems.
They also create significant energy savings and reduce line interference.
A specific option -- the Active Front End enables the Altivar 61 to be used in installations where particularly low harmonic levels are required.
It also allows the Altivar 61 drive to operate on unstable line supplies.
The Altivar 61 drive incorporates advanced functions for optimum efficiency in the majority of applications in the industrial or commercial buildings sector.
- Ventilation
- Air conditioning
- Air purification / smoke extraction
- Fluid management
- Pumping and booster stations
- Irrigation stations
- Off-shore drilling rigs
The Altivar 61 drive meets stringent requirements due to its numerous integrated application functions while helping ensure the reliability of equipment with its protection and safety functions.
- Energy saving ratio / 2 or 5 point quadratic ratio
- Automatic catching a spinning load with speed detection
- Adaptation of current limiting according to speed
- Noise and resonance suppression due to the possibility of adjusting the switching frequency during operation up to 16 kHz depending on the rating and the possibility of making frequency skips
- Preset speeds
- Integrated PID regulator with preset PID references and automatic/manual (Auto/Man.) mode
- Electricity and service hours meter
- Fluid absence detection -- zero flow and limited flow detection
- Sleep function / wake-up function
- Customer settings with display of physical measurements (bar / I/s / °C)
Protection functions
- Motor and drive thermal protection / PTC thermal probe management
- Protection against overloads and overcurrents in continuous operation
- Machine mechanical protection via skip frequency function / output phase rotation
- Protection of the installation by means of underload / overload and zero flow detection
- Protection via management of multiple faults and configurable alarms
Safety functions
- Machine safety via the integrated Power Removal function.
-- This function stops the motor and helps preventing accidental restarts.
-- It complies with machine safety standard ISO 1389-1 category 3 and the standard for functional safety IEC/EN 61508 / SIL2 capability (safety control-signaling applied to processes and systems).
-- This safety function means that the drive can be installed as part of the safety system for an Electrical/Electronic/Programmable Electronic control system relating to the safety of a machine or industrial process.
- Means of the forced operation function with configurable fault inhibiting -- direction of operation and references help ensure installation safety
It has been designed for common fluid management applications in industrial and commercial buildings and infrastructures.
The Altivar 61 can increase the performance of equipment and reduce operating costs in buildings by optimizing energy consumption whilst improving user comfort.
The drive is designed to be environmentally-friendly
- Energy saving with a reduction in energy consumption of 70% for ventilation applications and 50% for pumping applications
- Reduction of fluid losses in distribution networks
- Use of 80% recyclable materials
- the Altivar 61 drive conforms to environmental standard ISO 14040 which defines a critical analysis of the product's impact on the environment
The Altivar 61 drive has been developed to meet the requirements of directives regarding the protection of the environment (RoHS / REACH / WEEE) as well as those of European Directives to obtain the CE mark.
The entire range is UL / CSA / DNV / C-Tick / NOM and GOST certified and conforms to international standards relating to electrical industrial control equipment IEC/EN 61800-2 and IEC/EN 61800-5-1.
The need for electromagnetic compatibility was taken into account at the outset when designing the drive. The entire range conforms to international standard IEC/EN 61800-3.
The Altivar 61 drive complies with the requirements of safety standards for applications in explosive atmospheres (ATEX). Please refer to the ATEX guide which is available on our website www.schneider-electric.com.
The Altivar 61 range offers numerous variants to meet the requirements of applications in a wide variety of fields and in very harsh environments.
With these variants -- the Altivar 61 range offers ready-to-use or modular solutions that can adapt to your needs.
Its numerous and comprehensive options enable it to be adapted and incorporated into electrical installations / sophisticated control systems / infrastructures and building management systems.
They also create significant energy savings and reduce line interference.
A specific option -- the Active Front End enables the Altivar 61 to be used in installations where particularly low harmonic levels are required.
It also allows the Altivar 61 drive to operate on unstable line supplies.
The Altivar 61 drive incorporates advanced functions for optimum efficiency in the majority of applications in the industrial or commercial buildings sector.
- Ventilation
- Air conditioning
- Air purification / smoke extraction
- Fluid management
- Pumping and booster stations
- Irrigation stations
- Off-shore drilling rigs
The Altivar 61 drive meets stringent requirements due to its numerous integrated application functions while helping ensure the reliability of equipment with its protection and safety functions.
- Energy saving ratio / 2 or 5 point quadratic ratio
- Automatic catching a spinning load with speed detection
- Adaptation of current limiting according to speed
- Noise and resonance suppression due to the possibility of adjusting the switching frequency during operation up to 16 kHz depending on the rating and the possibility of making frequency skips
- Preset speeds
- Integrated PID regulator with preset PID references and automatic/manual (Auto/Man.) mode
- Electricity and service hours meter
- Fluid absence detection -- zero flow and limited flow detection
- Sleep function / wake-up function
- Customer settings with display of physical measurements (bar / I/s / °C)
Protection functions
- Motor and drive thermal protection / PTC thermal probe management
- Protection against overloads and overcurrents in continuous operation
- Machine mechanical protection via skip frequency function / output phase rotation
- Protection of the installation by means of underload / overload and zero flow detection
- Protection via management of multiple faults and configurable alarms
Safety functions
- Machine safety via the integrated Power Removal function.
-- This function stops the motor and helps preventing accidental restarts.
-- It complies with machine safety standard ISO 1389-1 category 3 and the standard for functional safety IEC/EN 61508 / SIL2 capability (safety control-signaling applied to processes and systems).
-- This safety function means that the drive can be installed as part of the safety system for an Electrical/Electronic/Programmable Electronic control system relating to the safety of a machine or industrial process.
- Means of the forced operation function with configurable fault inhibiting -- direction of operation and references help ensure installation safety
Degree of pollution
3
Related Documents
Name | Last Update | Language |
---|---|---|
Schneider Electric - Altivar 61-61Plus - Catalogue.pdf | 08 Aug 2022 | English (US) |